Italy

Hb NEXT

Hb NEXT is the new reversed-phase cation exchange HPLC analyzer designed to deliver precise and accurate HbA1c values in the presence of the main hemoglobin variants and to meet the most stringent guidelines for diabetes diagnosis and monitoring.

The reliable results are traceable to the IFCC reference method. This cutting-edge, fully automated system combines HPLC precision and variant detection with the rapid throughput your laboratory needs. Hb NEXT offers high performance, user-friendly steps, and no sample preparation. Most importantly, it delivers results clinicians can trust.

 

 

 

 

 

 

FULLY AUTOMATED AND HIGHLY EFFICIENT WORKFLOW

 

 

  • High processing speed: 60 sec/test
  • High column lifetime: at least 6000 tests
  • Minimized operator intervention
  • Easy-to-maintain

SAMPLE MANAGEMENT

  • Automatic sample identification via barcode scanning
  • Sample type (whole blood, anemic samples or pre-hemolysed samples) can be automatically recognized by the analyzer by using dedicated sample racks
  • Closed tube sampling for maximum safety to the operator
  • Automatic sample stirring function

REAGENT MANAGEMENT

  • Two reagent containers are available for each eluent, to allow the substitution of the empty container without interrupting the measurement routine
  • Full compatibility between different lots of eluents and column
  • Reagent traceability via barcode scanning

Brochure available HERE

 

Download_PDF

Intended use

Quantification of stable glycated hemoglobin (HbA1c) in human whole blood in the presence of hemoglobin variants for the diagnosis and monitoring of diabetes mellitus
Samples Human whole venous blood and pre-hemolysed samples
Measurement principle Reversed-phase cation exchange chromatography
Measurement unit Peak calibration and result calculated in SI units (mmol/mol) - Conversion to NGSP % value via IFCC master equation
Measurement resolution 0.1 mmol/mol
Quantitative range HbA1c: 9-100 mmol/mol, 3-20%
Processing speed 60 seconds per sample
Throughput 60 samples/hr
Minimum sample volume 1 mL in standard whole blood containers
Injection volume Whole blood samples: 5-10 μL / Pre-hemolysed samples: 200-500 μL
Sample container Whole blood sample tube: (12.3-15 mm diameter) × (75-100 mm height) / Mixing function only with tubes of regular size: (12.3-13.2 mm diameter) × (75-85 mm height)
System operating environment Temperature: 10-30 °C; humidity: 20-80% R.H. (no condensation)
Column lifetime At least 6000 tests
Sample identification internal barcode reader
Display and printer 10.1" TFT color LCD screen and thermal printer
Power supply and consumption analyzer AC 100V~240V, 50-60 Hz, 250 VA
Dimensions LxWxH 760x765x770 mm
Weight 64 kg
Connectivity LIS: RS-232, RJ45 Ethernet, bidirectional protocol
55607 HbNEXT ANALYZER 1pcs
55604 HbNEXT ANALYTICAL COLUMN 1pcs
55599 HbNEXT ELUENT A 1 x 800 mL
55600 HbNEXT ELUENT B 1 x 800 mL
55601 HbNEXT ELUENT C 1 x 800 mL
55603 HbNEXT HAEMOLYSIS SOLUTION H 1 x 2500 mL
55606 HbNEXT HbA1c CALIBRATOR 2 x 0.1 mL
55605 HbNEXT HbA1c CONTROL 2 x 0.1 mL

 

HbNEXT is available in the following A.Menarini Diagnostics countries:

Austria: https://www.menarinidiagnostics.at

Benelux: https://www.menarinidiagnostics.be

France: https://www.menarinidiagnostics.fr

Greece: https://www.menarinidiagnostics.gr

Italy: https://www.menarinidiagnostics.it

Nordics: https://www.menarinidiagnostics.se

Portugal: https://www.menarinidiag.pt

Spain: https://www.menarinidiag.es

UK: https://www.menarinidiag.co.uk

Our values

10 core values have influenced the progress of our group.

READ MORE »